Home
Products
Support
About TOA
For the Press
Contact Info



New Products

Training

Amplifiers &
Mixer/Amplifiers


Modules

Speakers

Network Audio

Mixers

Digital Signal Processors

Wired & Wireless Microphones

Conference Systems

Digital Message Repeaters

Megaphones

Tuner, Timer &
Impedance
Meter


CCTV/Video Surveillance

Intercom Systems

Alphanumeric

How To Buy

Search TOA

Discontinued Products

Installation Profiles

Repair Contacts

Site Map



N-8000 Series
IP Network Intercom Systems

Award Winner!
2006 N
SCA Innovations in Technology
Security/Fire/Life Safety Category

How to Buy

The N-8000 Series IP Network Intercom offers flexible communications for up to 1280 stations on existing corporate local and wide area data networks. Built on TOA’s proven NX-100 network audio technology, the new IP Intercom products occupy minimal network bandwidth (130 kbps maximum) for station-to-station calls and can be controlled and monitored through software or web browser. Programmable system functions include 160 paging zones, time-based call forwarding and scan monitoring.

The backbone of the new system is the compact N-8000EX Exchange which supports 16 stations and occupies only one rack space. Features include a 10/100BaseT port for connection to standard network hardware and two paging audio outputs. Larger systems can be easily configured with up to 80 exchanges and 1,280 stations. The economy N-8010EX IP Intercom Exchange, featuring one speech link, is available as a lower-cost alternative to the four-link N-8000EX IP Intercom Exchange. The N-8000MI Multi-Interface Unit features telephone interface, BGM input, paging outputs, control signaling plus functions as an interface to legacy TOA EXES intercom systems.

The N-8000 station lineup includes both two-wire and Ethernet stations:

Two-wire stations include The N-8000MS Multifunctional Master Station, equipped with a 32 character alphanumeric LCD display, handset and speed dial functions; the N-8010MS Standard Master Station with keypad and handset; the N-8020MS Industrial Master Station, built to withstand severe environmental conditions; and the N-8011MS Hands-Free Master Station offering hands-free simultaneous two-way (duplex) communication via an innovative ambient noise sensing function. Other two-wire stations include the N-8030MS Flush-Mount Hands-free Master Station, N-8040DS Indoor Sub-station and Q-N-8040WP Outdoor  Sub-station. For custom station applications, TOA offers the N-8031SB Hands-free Master Station Board Unit and the N-8050SB Hands-free Substation Board Unit. Station line monitoring is also available via software, web browser or station display.

Ethernet stations include the N-8500MS IP Multi-function Master Station, which has a built-in Ethernet connection for direct network connection, a 32 character alphanumeric LCD display, and handset and speed dial functions. The N-8540DS IP Indoor Sub-station also connects directly to the network and includes a vandal-resistant call-switch and control output for door release. A weather-resistant version is also available, model Q-N-8540WP IP Outdoor Sub-station.

Also see the VS-900 Security Intercom System and NX-100 Network Audio.



Spec. Sheet
(PDF, 1.2Mb)

Manual
(PDF, 6.1Mb)
Estimate
Worksheet
(PDF, 61 kb)
A&E Spec
(PDF, 168kb)
CAD Data
(ZIP, 3.5Mb)

Software v1.38
(ZIP, 4Mb)

FEATURES

  • Scalable network communications for up to 1280 stations over data networks (LAN/WAN)
  • Flexible configuration options for existing cabling and network infrastructure
    Station Options:
    • IP Stations with Ethernet port connect directly to the network (up to 80 stations)
    • Connect up to sixteen two-wire stations to compact Network Exchange (up to 80 exchanges for up to 1,280 stations)
  • Occupies minimal network bandwidth — 130 kbps max. (station to station call)
  • Hands-free full-duplex conversation
  • Control and monitor through software and web browser
  • Versatile features including 160 zone paging, time-based call forwarding and scan monitoring

SYSTEM EXCHANGES
(for two-wire stations)

N-8000EX
IP Intercom Exchange

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node ( 80 max.)
  • Sixteen (16) station capacity
  • Stations connect to exchange via two-wire twisted pair
  • Provides 48 VDC to each station
  • Speech links: 4 internal / 8 external
  • Two (2) audio paging outputs (0 dBV)
  • Two (2) relay outputs
  • Includes rack-mount and wall-mount brackets
Manual (PDF, 346kb)
Firmware v1.42  (N-8000EX) (ZIP, 586kb)


(Click image for large view)

N-8010EX
IP Intercom Exchange (economy)

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node ( 80 max.)
  • Sixteen (16) station capacity
  • Stations connect to exchange via two-wire twisted pair
  • Provides 48 VDC to each station
  • Speech links: 1 internal / 2 external
  • Includes rack-mount and wall-mount brackets

Manual (PDF, 346kb)
Firmware v1.12  (N-8010EX) (ZIP, 586kb)

N-8000MI
Multi-Interface (BGM, TEL, EXES, Control I/O)

  • 10/100BaseTX Ethernet network connection
  • Occupies one network node ( 80 max.)
  • Audio Inputs for BGM, External Tone or Paging
    • Two audio line inputs (0 dBV) with two trigger inputs
    • Two audio line outputs (0 dBV) with two relay outputs
  • Contact Bridge
  • Sixteen contact inputs
  • Sixteen relay outputs
  • Telephone Interface (E&M type), two channels
  • Interface for connecting to legacy EXES-6000 systems (Q-TI-600 also required)
  • Includes rack-mount and wall-mount brackets
Manual (PDF, 253kb)
Firmware v1.12  (N-8000MI) (ZIP, 517kb)


(Click image for large view)

Q-TI-600
Tie-line Interface for EXES-6000 to N-8000

  • Provides two tie-line links for connection between legacy EXES-6000 systems (CP-66 version) and N-8000 systems
  • Requires two available open EXES station ports
  • Interface for connecting to legacy EXES-6000 systems (N-8000MI also required)
  • Includes rack-mount brackets

Spec Sheet (PDF, 64kb)


IP STATIONS
(connect directly to network)

N-8500MS
Multifunction IP Master Station

  • Connects directly to network (10/100Base TX)
  • Occupies one network node ( 80 max.)
  • Power-over-Ethernet compatible or optional power supply, model AD-1210P
  • Two RJ-45 network connectors (one for network, one for PC)
  • Alphanumeric LCD display (32 character)
  • Handset or hands-free duplex communication
  • Eight user-programmable speed dial keys
  • Headset terminal
  • External speaker terminal (0.6 W / 8 ohms)
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 139kb)
Firmware v1.12  (N-8500MS/N-8540DS) (ZIP, 738kb)

N-8540DS
Indoor IP Substation

  • Connects directly to network (10/100Base TX)
  • Occupies one network node (80 max.)
  • Power-over-Ethernet compatible or optional power supply, model AD-1210P
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • IP54 rated
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A

Manual (PDF, 60kb)

Firmware v1.12  (N-8500MS/N-8540DS) (ZIP, 738kb)

Q-N8540WP
Outdoor IP Substation

  • Connects directly to network (10/100Base TX)
  • Occupies one network node (80 max.)
  • Power-over-Ethernet compatible or optional power supply, model AD-1210P
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A

Specification Sheet (PDF, 60kb)
Manual (PDF, 60kb)

Firmware v1.12  (N-8500MS/N-8540DS) (ZIP, 738kb)


TWO-WIRE STATIONS
(connect to N-8000EX or N-8010EX Network Exchange)

N-8000MS
Multifunction Master Station

  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Alphanumeric LCD display (32 character)
  • Handset or hands-free duplex communication
  • Eight user-programmable speed dial keys
  • Headset terminal
  • External speaker terminal (0.6 W / 8 ohms)
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 203kb)

N-8010MS
Standard Master Station

  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Handset or hands-free duplex communication
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 203kb)

 

 

N-8011MS
Handsfree Master Station

  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • Optional wall-mount bracket, model YC-290

Manual (PDF, 91kb)

 

N-8020MS
Industrial Master Station

  • Heavy duty dustproof and waterproof construction (IP54 rating)
  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Handset or hands-free duplex communication
  • External speaker terminal (0.6 W / 8 ohms)
  • Control output
  • Optional wall-mount bracket, model YC-280

Manual (PDF, 203kb)

 

N-8031MS
Panel-Mount Master Station

  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • External dial inputs (7, 8, 9 and C keys)
  • Optional Handset, model RS-191
  • Optional flush-mount back-box, model YC-241
  • Optional surface-mount back-box, model YC-251
  • Also available as PCB assy., model N-8031SB

Manual (PDF, 196kb)

 

N-8050DS
Indoor Substation

  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • IP54 rated
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A
  • Also available as PCB assy., model N-8050SB

Manual (PDF, 74kb)

 

Q-N8050WP
Outdoor IP Substation

  • Two-wire connection to N-8000EX or N-8010EX Exchange
  • Hands-free duplex communication
  • Separate mic and speaker
  • Control output (open collector)
  • IP54 rated
  • Optional flush-mount back-box, model YC-150
  • Optional surface-mount back-box, model YS-13A
  • Also available as PCB assy., model N-8050SB

Specification Sheet (PDF, 60kb)
Manual (PDF, 60kb)

 


CUSTOM TWO-WIRE STATION ASSEMBLIES
(connect to N-8000EX or N-8010EX Network Exchange)

N-8031SB
Panel-Mount Master Station PCB

  • N-8031 PCB for custom station applications
  • Speaker and microphone included
  • External dial inputs (7, 8, 9 and C keys) plus switch matrix connection
  • LED Status Indicator output
  • Optional Handset, model RS-191

Manual (PDF, 88kb)

N-8050SB
 Substation PCB

  • N-8050DS PCB for custom station applications
  • Speaker and microphone included
  • Control output (open collector)
  • Call switch input
  • LED Status Indicator output

Manual (PDF, 51kb)


Google
Search WWW Search toaelectronics.com


HOME | PRODUCTS | CUSTOMER SUPPORT | ABOUT TOA NEWS | CONTACT US
SITE MAP | CAREERS
  TOA Electronics, Inc., 601 Gateway Blvd, #300, So. San Francisco, CA 94080
TEL: (650) 588-2538 (800) 733-7088