VS-900
Security Intercom Systems

How to Buy

New! N-8000 IP Network Intercom Systems!

TOA VS-900 SECURITY INTERCOM SYSTEMS provides reliable and intelligible voice communication for critical security applications, including corporate security, correctional institutions, educational facilities, hospital access points, and parking structures. For over 35 years, TOA has developed a proven track record of innovative, reliable intercom products, including the groundbreaking EXES and IC-100 systems. The TOA VS-900 system is UL and CUL Listed and manufactured to ISO-9001 standards to ensure continuous operation for extended periods.

Ideal for applications with multiple remote "sub" stations calling in to one or more "master" stations, the VS-900 has a wide range of standard and software programmable features, including comprehensive Call-Forwarding to allow system operators freedom of movement and most importantly, to ensure that no calls go unanswered. The VS-900 integrates easily with access control and video surveillance equipment via a simple RS-232 communications protocol. Other features include telephone system integration, paging and external source distribution, event logging and recording outputs.

The VS-900 scalable architecture allows the most cost effective configuration for each application with easy expansion as the size of the facility grows. Each exchange mainframe supports up to 4 master stations and 64 remote sub-stations. For large systems, exchanges can be expanded or "tie-lined" to provide up to 64 master stations and 1,024 remote sub-stations. The master stations can be either the TOA MS-900 or standard off-the-shelf single line telephones with support for Caller-ID signaling. Remote Sub-stations include Economy, Indoor, Outdoor, and Panic models, each with heavy-duty plate and call switch. Direct select interface cards provide relays, LED drivers and switch inputs for custom consoles and annunciator panels.

The VS-900 Security Intercom System is backed with a two-year warranty.



Brochure
(PDF, 137 kb)

Intl. Version
(PDF, 445 kb)
 

Spec Sheet
(PDF, 352 kb)
Intl. Version
(PDF, 453 kb)

 

Installation Profile
(PDF, 180 kb)

A&E Spec.
(PDF, 196 kb)
A&E Spec. (DOC, 137 kb)
Manuals
Installation Manual (PDF, 1.6 Mb)
Operation Manual (PDF, 9577 kb)
Software Manual (PDF, 359 kb)
VS900DI Direct Select Manual (PDF, 273 kb)
RS-190/191 Manual (PDF, 80 kb)
RS-232 Control Protocol (PDF, 462 kb)
CAD Data (ZIP/DWG, 737 kb)
Software (v1.4)
(ZIP, 1.8 Mb)

Application Note
External Amp or Speaker Connection
(PDF, 602 kb)

FEATURES
  • Security Intercom Systems for critical applications such as corporate, correctional, educational, government, military, parking structures, police, and others.
  • "Remote Sub-to-Master" and "Master-to-Master" Station communication.
  • Proven TOA Quality and Reliability
  • UL-Listed, manufactured to ISO-9001 standards.
  • User-Friendly Installation, Setup and Maintenance
  • Modular Design scalable for cost-effective system configurations with easy system expansion.
  • Station Capacity:
    • Single Exchange: 4 Master stations and 64 Remote Sub-stations
    • (Up to) 16 Tie-lined Exchanges: 64 Master stations and 1,024 Remote Sub-stations
  • Flexible Programming and Control Software — For setup and maintenance of multiple exchanges from one PC, remotely via modem or via network using an RS-232-to-Ethernet converter.
  • Security System Integration — Communication protocol available for remote control and monitoring of intercom system functions from external devices.
  • Comprehensive Call Forwarding Features — Time-based, No-Answer, Busy and C/O line to prevent unanswered calls and allow attendant mobility
  • Recording Outputs for individual conversation recording of each master station, telephone master station and telephone line port with start/stop control activation.
  • Event Logging all system events are date and time-stamped for PC archiving.
  • Master Station Flexibility supports TOA MS-900 or standard Caller-ID analog telephones.
  • Console Master Interface allows custom master station fabrication with headset, microphone, speaker, and key ports.
  • Durable Remote Sub-stations choose from Economy, Indoor, Outdoor, and Panic models, each with heavy-duty plate and call-switch.
  • Simple Wiring each station connects to exchange via: (STP) shielded, twisted pair (Remote Sub-stations RS-150, RS-160, RS-170 & RS-180) or two twisted pairs (MS-900 Master Station and RS-190 Remote Sub-stations).
  • Extended Cable Runs — Master Stations: 7,546 ft., Remote Sub-stations: 4,265 ft. and Tie-Lined Exchanges: 4,921 ft. (#20 AWG)
  • Site Connector Interface — Allows remote exchange connections with fiber optic or other media converters.
  • Telephone Interface supports two outside C/O telephone lines or trunks.
  • Paging Interface for external amplifier zone distribution with sixteen control ports.
  • External Source Input for station and external amplifier zone distribution with four trigger inputs.
  • Two Year Warranty

APPLICATIONS

  • Access Control
  • Corporate Security
  • Correctional Institutions
  • Educational Facilities
  • Government
  • Hospital Access Points
  • Industrial
  • Military
  • Parking Structures
  • Police
  • Restricted Door Access

 


VS-900MF

System Exchange Main Frame

  • Mainframe for system cards.

  • Supports up to 4 Master Stations and 64 Remote Stations.

  • Requires one PU-200 Power Supply for up to 32 Remote Stations and two PU-200 for 33 - 64 Remote Stations.

  • 24V DC Input for backup power supply.

  • Power ON/OFF Switch.

  • Mircosoft Windows ® - based PC required for system programming.

  • Two RS-232 Ports for programming and log file access.

  • Rack Mount (10RU) brackets included.

  • Optional wall-mount bracket, Model YC-303

Specification Sheet (PDF, 90kb)

 

 

MS-900

Master Station

  • Up to four MS-900 can be used per VS-900MF using two VS-900MS cards.

  • Connects to VS-900MS card using two-twisted pair wires.

  • Standard RJ-11 telephone jack.

  • Supports half-duplex and full-duplex communication.

  • Handset and hands-free speaker / microphone.

  • Alpha-numeric, 12 character LCD display.

  • Digital clock display.

  • In-use indicator.

  • Eight programmable auto-dial keys.

  • Press-to-Talk, Redial and Transfer keys.

  • Station number directory.

  • Adjustable speaker volume and microphone sensitivity.

  • Speaker High/Low volume selector switch.

  • External speaker terminals for high ambient noise areas.

  • Wall-mount bracket included.

Specification Sheet (PDF, 173kb)

 

 

VS-900MS

Master Station Line Card

  • Provides two MS-900 Master Station ports.

  • Provides two Recording Line outputs.

  • Provides two Recording Control outputs (Open Collector type).

  • Removable terminal blocks.

  • Up to two VS-900MS cards can be installed per VS-900MF.

Specification Sheet (PDF, 123kb)

 

 

VS-900AL

Telephone Master Station Line Card

  • Two standard analog telephone ports (Telephone equipment supplied by other vendors).

  • Caller-ID Signaling supported.

  • Two Recording Line outputs.

  • Two Recording Control outputs (open collector circuit).

  • Removable terminal blocks.

  • Up to two VS-900AL cards can be installed per VS-900MF.

Specification Sheet (PDF, 136kb)

 

 

RS-150

Economy Indoor Remote Sub-Station

  • Provides half-duplex communication.

  • Hairline brushed stainless steel faceplate, #14 Gauge.

  • Connects to VS-900RS card using shielded, twisted pair wiring.

    • Fiber optic interfaces available from other vendors.

  • Mounts in two-gang, 2" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (64) sixty-four RS-150 Remote Stations can be used per VS-900MF using four VS-900RS cards.

Specification Sheet (PDF, 107kb)

 

 

RS-160

Indoor Vandal Resistant Remote Sub-Station

  • Provides half-duplex communication.

  • Heavy-duty brushed stainless steel faceplate,           #11 Gauge.

  • Vandal resistant call button.

  • Connects to VS-900RS card using shielded, twisted pair wiring.

    • Fiber optic interfaces available from other vendors.

  • Mounts in two-gang, 2.25" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (64) sixty-four RS-160 Remote Stations can be used per VS-900MF using four VS-900RS cards.

Specification Sheet (PDF, 109kb)

 

 

RS-170

Outdoor Vandal Resistant Remote Sub-Station

  • Provides half-duplex communication.

  • Heavy-duty brushed stainless steel faceplate,            #11 Gauge.

  • Vandal resistant call button.

  • Weather resistant conformal printed circuit board coating.

  • Connects to VS-900RS card using shielded, twisted pair wiring.

    • Fiber optic interfaces available from other vendors.

  • Mounts in two-gang, 2.25" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (64) sixty-four RS-170 Remote Stations can be used per VS-900MF using four VS-900RS cards.

Specification Sheet (PDF, 115kb)

 

RS-180

Outdoor Panic Vandal Resistant Remote Sub-Station

  • Provides half-duplex communication.

  • Heavy-duty brushed stainless steel faceplate,           #11 Gauge.

  • Red vandal resistant call button.

  • Red Call Assurance LED for ADA-compliance.

  • Labeling area for ADA-compliant message.

  • Control output - open collector type for external relay control.

    • Open collector circuit is activated when the "Call" button is pressed and stays active until the call is completed.

    • Open collector circuit is typically used to trigger a strobe light at the remote station location to indicate the station is in use. (Strobe light and relay supplied by other vendors.)

    • Open collector circuit is not remote controllable from other devices.

  • Weather resistant conformal printed circuit board coating.

  • Connects to VS-900RS card using shielded, twisted pair wiring.

    • Fiber optic interfaces available from other vendors.

  • Mounts in two-gang, 2.25" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (64) sixty-four RS-180 Remote Stations can be used per VS-900MF using four VS-900RS cards.

Specification Sheet (PDF, 138kb)

 

VS-900RS

Remote Station Line Card

  • Provides (16) sixteen Remote Sub-Station ports.

  • Compatible with RS-150, RS-160, RS-170 and RS-180 Remote Sub-Stations.

  • Provides two talk paths/speech links (one speech, one speech/paging).

  • Supports half-duplex communication.

  • Paging Input and Output for external paging amplifier connection.

    • A 30 watt paging amplifier is required if the Remote Stations connected to the VS-900RS will be used in a paging zone.

      • TOA's BG-130 30 watt paging amplifier is recommended for this application.

      • One paging amplifier is required per VS-900RS card in the exchange main frame which participate in the paging operation.

  • Removable terminal blocks.

  • Up to four VS-900RS cards can be installed per VS-900MF.

Specification Sheet (PDF, 164kb)

 

 

RS-190

Indoor Remote Sub-Station

  • Provides full-duplex communication.

  • Recommended for elevators and other applications.

  • Hairline brushed stainless steel faceplate, #14 Gauge.

  • Connects to VS-910RS card using two, twisted pair wires.

  • Red call in progress LED.

  • Control output - open collector type for external relay control.

    • Open collector circuit is activated when the "Call" button is pressed and stays active until the call is completed.

    • Open collector circuit is typically used to trigger a strobe light at the remote station location to indicate the station is in use. (Strobe light and relay supplied by other vendors.)

    • Open collector circuit is not remote controllable from other devices.

  • Mounts in two-gang, 2.25" deep electrical box with adapter ring (supplied by other vendors).

  • Up to (64) sixty-four RS-190 Remote Stations can be used per VS-900MF using four VS-910RS cards.

  • Optional Handset available RS-191.

Specification Sheet (PDF, 117kb)

 

 

RS-191

Optional Handset for RS-190

  • Lifting the handset provides full-duplex handset conversation.

  • Recommended for environments with high ambient noise to assure intelligible conversation or to offer "telephone handset like" privacy.

  • Dynamic type handset receiver.

  • Electret condenser type handset transmitter.

  • Pale White color.

  • ABS resin finish.

Specification Sheet (PDF, 44kb)

 

 

 

VS-910RS

Remote Sub-Station Interface Card

  • Provides (16) sixteen Remote Station ports.

  • Provides full-duplex communication.

  • Used exclusively with RS-190 Remote Sub-Stations.

  • Connects to RS-190 remote station using two, twisted pair wires.

  • Provides two speech paths, either of which can be used for remote station paging.

  • Removable terminal blocks.

  • Up to four VS-910RS cards can be installed per VS-900MF.

Specification Sheet (PDF, 166kb)

 

 

VS-900CO

C/O Telephone Interface Card

  • Two Outside Telephone (C/O) Line ports.

  • Two Recording Line outputs.

  • Two Recording Control outputs (open collector circuit).

  • Removable terminal blocks.

  • One VS-900CO cards can be installed per      VS-900MF.

       Note: Paging from the Outside Telephone Line(s) is not supported. Custom

                firmware for the VS-900MF must be obtained from TOA to support this

                special functionality.

 

Specification Sheet (PDF, 123kb)

 

 

VS-900AF

Audio Function Card

  • Paging Line output.

  • Sixteen Paging Control outputs (open collector circuit) to control the mute circuits of the paging zone amplifiers permitting single zone or All-Call paging.

    • Paging Amplifier recommendations include TOA's: BG-M series, A-700 series and A-900MK2 series.

  • External Source Line input.

  • Four External Source Trigger inputs for zone distribution.

  • Link for Conference and Emergency Conference features.

  • Removable terminal blocks.

  • One VS-900AF card can be installed per VS-900MF.

Specification Sheet (PDF, 80kb)

 

 

VS-900TI

Tie-Line Interface Card

  • Required in each VS-900MF exchange in a multi-exchange tie-lined system (16 exchanges maximum).

  • Multi-drop (bussed) configuration simplifies wiring.

  • Up to four Voice Links (4x Send/4x Receive), two twisted pair wiring for each voice link.

  • One Data Link, RS-485, requires (STP) shielded, twisted pair wiring.

  • Removable terminal blocks.

Specification Sheet (PDF, 107kb)

 

 

VS-900SC

Site Connector Tie-Line Interface for Optical Fiber Interfacing

  • Allows you to connect exchanges voice links using standard audio optical fiber interfaces or other media converters (supplied by other vendors).

  • Combines up to four voice links from three exchanges.

  • Two exchange systems requiring optical fiber or other media connection do not require the VS-900SC.

  • Each VS-900SC requires one external power supply, model PU-200.

  • To determine the number of VS-900SC, subtract "two" from the total number of VS-900MF Exchange Main-frames. For example, a system with ten VS-900MF will require eight VS-900SC.

       Note: The VS-900SC does not support or connect to the VS-900TI RS-485

                Data Line (CN6). RS-485 optical fiber interfaces or other media

                converters are available from other vendors.

 

Specification Sheet (PDF, 166kb)

 

 

VS-900DI

Direct Select/Master Station Interface Card

  • Supports up to (32) VS-910DI Direct Select I/O cards.

  • Connects between a single MS-900 Master Station and a single VS-900MS master station port. Each MS-900 master station or custom master station in the system that requires this functionality will require (1) VS-900DI and the appropriate number of       VS-910DI up to a maximum of (32).

  • Use standalone without MS-900 to provide interface for custom master stations.

  • Headset port is provided.

  • Microphone input is provided.

  • Speaker output (1 W, 8 Ohms) is provided.

  • Key Input terminals (XFER, PTT, C).

  • In-use Indication output is provided.

  • Requires 24V DC (1A) power supply, model XPS-24VS per (1) VS-900DI and (2) VS-910DI.

  • Mountable in installer-supplied console or enclosure (from other vendors).

Specification Sheet (PDF, 209kb)

 

 

VS-910DI

Direct Select I/O Card

  • Connects to VS-900DI (Maximum of 32 VS-910DI per VS-900DI).

  • 32 Programmable Relay outputs (24V DC, 1A).

  • 32 Programmable Call-LED drivers (Open collector type).

  • 32 Programmable Direct Select Switch inputs.

  • Relays Programmable to Activate at Call-In or Call-Answer.

  • Requires 24V DC (1A) power supply, model XPS-24VS.

  • Mountable in installer-supplied console or enclosure (from other vendors).

Specification Sheet (PDF, 189kb)

 

 

XPS-24VS

24V DC Power Supply                                                         Picture not available

  • Provides 24V DC power up to 3 Amps maximum.

  • Used with VS-900DI and VS-910DI.

 

PU-200

Power Supply for VS-900MF

  • Connects to the VS-900MF and provides two 20V AC outputs.

  • One PU-200 supports 1 or 2 VS-900RS or 1 or 2 VS-910RS.

  • Two PU-200 supports 3 or 4 VS-900RS or 3 or 4 VS-910RS.

  • Wall-mount brackets included.

  • Optional Rack-mount panel, model PN-100B.

Specification Sheet (PDF, 145kb)

 

 

PN-100B

Rack-Mount Panel for (2) PU-200 (4RU)

Specification Sheet (PDF, 34kb)

 

 

YC-303

Wall-Mount Bracket for VS-900MF

 

Specification Sheet (PDF, 67kb)

 

 

 

 

 

XWJ-100F

Flush-mount Modular Jack                                                  Picture not available

  • For MS-900 or telephone master station

 

XWJ-100S

Surface-mount Modular Jack                                               Picture not available

  • For MS-900 or telephone master station

 

 

 