Power Source
                        
                      24 V DC (operating range: 15 – 40 V DC, supplied from the VM-3000 system)
                     
                                    
                                                 
                                                                           
                      Operation
                        
                      Emergency key, Evacuate key, Alert key, Emergency reset key,
CPU switch, Reset key
                     
                                    
                                                 
                                                                           
                      Current Consumption
                        
                      120 mA (RM-300MF), 660 mA (with 3 RM-320Fs connected)
                     
                                    
                                                 
                                                                          
                                    
                                                 
                                                                           
                      Frequency Response
                        
                      200 Hz – 15 kHz
                     
                                    
                                                 
                                                                           
                      Signal to Noise Ratio
                        
                      55 dB or more
                     
                                    
                                                 
                                                                           
                      Microphone
                        
                      Unidirectional dynamic microphone with talk key, compressor (on/off switchable)
                     
                                    
                                                 
                                                                           
                      Volume Control
                        
                      Microphone volume control, buzzer volume control
                     
                                    
                                                 
                                                                           
                      Maximum Cable Length
                        
                      Total 800 m
                     
                                    
                                                 
                                                                           
                      Connection Cable and Connector
                        
                      Main line: Shielded CPEV cable (each one pair of Audio line, Data line,
                     
                                    
                                                 
                                                                           
                      Terminal
                        
                      Power supply line) or Category 5 Shielded Twisted-Pair straight cable for LAN (CAT5-STP), M3 screw terminal
                     
                                    
                                                 
                                                                           
                      Number of Connectable RM-320F
                        
                      Max. 3 units
                     
                                    
                                                 
                                                                           
                      Indicator
                        
                      Power Indicator, Emergency Indicator, Communication Failure Indicator,
CPU OFF Indicator, Evacuation Announcement Indicator,
Alert Announcement Indicator, Emergency Reset Indicator,
Microphone In-Use Indicator, External Emergency Equipment In-Use Indicator
                     
                                    
                                                 
                                                                           
                      Operating Temperature
                        
                      –5 to +45 °C
                     
                                    
                                                 
                                                                           
                      Operating Humidity
                        
                      5 to 95%RH (no condensation)
                     
                                    
                                                 
                                                                           
                      Finish
                        
                      ABS resin, blueish gray (PANTONE 538 or its equivalent)
                     
                                    
                                                 
                                                                           
                      Dimensions
                        
                      200 (w) x 215 (h) x 82.5 (d) mm
                     
                                    
                                                 
                                                                          
                                    
                               
              
                              
              
              
                
                  Please download Datasheet to access full specifications.
                
               
              
             
          
          
                      
              
                Fire station with easy-to-use hand-held microphone with talk button. 4 Emergency control buttons, of which a key to trigger the emergency mode with folding safety cover, the other buttons to start warning and evacuation messages and termination of the emergency mode. The intercom is keyboard extensions on expandable up to 65 keys with which other features are possible, including:
 
- Triggering alerts from the text memory in specific sections of the fire
- Triggering of evacuation messages from the text memory in specific sections of the fire
- Manual announcements in selectable ranges 
- standard-compliant acoustic and optical display specific error messages
 
Firmly integrated failed error communication between station and headquarters, CPU errors and level, ads for readiness. Built-in speaker to the acoustic error message. Adjustable microphone and speaker levels.
In the hand-held microphone of built-in beeper to monitor the MIC capsule including the acoustic-electric conversion. Monitoring of control and audio paths, as well as the preamplifier according to EN 54-16, 
VDE 0833-4 and VDE 0828-1 (EN 60849). 
As an additional safety feature can failure of the digital control, CPU failure of the intercom is switched off and announcements in all areas be discontinued.
Wall mount included.
 
The station is along with the VM-3000 voice alarm system certified by a notified body (notified) according to EN 54-16.
               
             
          
                      
              
                              
                                
                  